Sentinel Industrial Sensors

Module:SIOL-M12A-16SAP/EX

IO-Link Hub

SIOL-M12A-16SAP/EX is an IO-Link Hub designed for flexible field-level I/O expansion in industrial automation systems. It connects multiple digital input and output signals through one IO-Link interface, helping users simplify wiring, reduce cabinet space, and integrate sensors and actuators more efficiently in distributed machine installations.

Full Technical Specification

Specification

Value

Supply voltage

24VDC ± 10%

Operating current

<100mA

Working and load power supply

≤ 4A(UI Ub); Note: IO-Link Master provides power, Master parameters must be considered

Input

Number of channels

16(C0-C7)

Interface type

M12, 5-pin

Input type

PNP or NPN(Depends on the model)

Input impedance

3K

Input rated current

7mA

Input delay

3ms

Switch threshold

2mA/4mA 7V/11V

Electrical isolation mode

Optocoupler isolation

Sensor power supply

Maximum 150mA; C0...C3 Total currentmax1.2 A; C4...C7 Total currentmax1.2 A; The total CO-C7 current is limited to the maximum current of the Master port

Output

Number of channels

16(C0-C7)

Output type

PNP or NPN(Depends on the model)

Output current

0.2A;Max.0.5A;(Total maxcurrent<4A)

Output protection

Overload protection, overheating protection

Output protection reaction time

Approximately 20ms

Switching frequency

100HZ

Output voltage drop

0.6V

Electrical Isolation mode

Optocoupler isolation

IO-Link

Process data

6 bytes input,4 bytes output

Vendor ID

1317(0x0525)

Device ID

66148 (0x010264)

Number of ports

2

IO-Link port type

Class A

IO-Link specification

V1.1

Frame type

TYPE_2_V

Transmission rate

COM3 230.4 kbit/s

Minimum cycle time

3200us

ISDU

Supported

Block parameter operation

Not support

Data storage (DS) / Data storage lock

Supported

Operating temperature

-20-55℃

Product Features &Benefits

SENTINEL IO-Link Hubs are designed to collect field-level digital signals and connect them to the control system through a single IO-Link connection. They help simplify sensor and actuator wiring, support distributed installation close to the machine, and make I/O expansion more flexible for modern automation equipment.

IO

IO-Link Hub

Collects field-level digital I/O signals through one IO-Link connection

16 Digital I/O Points

Supports multiple sensor and actuator signals for machine-side expansion

Expandable Design

Allows flexible I/O expansion for changing automation requirements

V1.1

PNP Signal Support

Suitable for PNP digital input and output applications

M12 Field Wiring

M12 A-coded interfaces support quick and reliable field connection

IP67 Protection

Designed for distributed installation in industrial environments

Datasheet PDF

Download Product Datasheet

CAD

Download CAD files

Configuration File

Download Configuration File

Product overview

Download Product overview

Product Catalog

Download Product Catalog

Operation manual

Download Operation manual

You May Also Be Interested In

SIOL-M8-8DIP/LS

8-channel PNP input

SIOL-M8-16DIP

16-channel PNP input


Need Help Choosing

the Right Model?

Contact our engineering team for expert advice and custom solutions.

Scroll to Top