Sentinel Industrial Sensors

IO-Link Flow & Temperature Sensor for Data Center Liquid Cooling

Smart flow and temperature monitoring for water-based coolingoops, CDU systems,and rack-level coolant circuits.

Flow + Temperature

IO-Link V1.1

Water-Blased Cooling Loops

1000 / CDU / Distribution

17+

Years Experience

200+

EU Clients

48h

Delivery Within EU

50+

Countries Served

Liquid Cooling Needs More Than Alarms. It Needs Clear Field Data.

Flow Deviation

Unintended flow drops cause hotspots and reduce system reliability.Real-time flow data helps prevent risks.

Temperature Drift

Slight temperature changes impact performance and officiency. Accurate temperalure data matters.

Standardized IO-Link Data

IO-Link V1.1 provides digital cyclic data and event data for smarter control and predictive maintenance.

Main Product: FMV-040-IOL Vortex Flow Sensor

Measuring principle

Kármán Vortex

Medium

water

Flow range

5 - 40 L/min (0.3 - 2.4 m³/h)

Flow accuracy

<3.0%F.S

Temperature range

0-100℃

Temperature accuracy

1℃

Pressure level

10bar,greatest pressure16bar

Interface

IO-Link(V 1.1),Class A

Output

NPN/PNP/Push-Pull, NO/NC, Hysteresis/Window programmable

Protection level

IP65

Data storage(DS)

Support

Typical Liquid Cooling Applications

01 cooling test bench

CDU Cooling Loop Monitoring

Monitor flow and temperature in CDU cooling loops.

02 cooling loop

Rack-Level Coolant Circuits

Ensure stable cooling at the rack level.

03 data center cooling

Pump Protection

Detect low-flow conditions and protect pumps.

04 pump temperature alarm

Filter Blockage Detection

Identify clogging early and avoid buildup.

05 filter blockage alarm

Heat Exchanger Monitoring

Monitor performance and prevent fouling.

06 heat exchanger temperature

Liquid Cooling Test Benches

Accurate data for testing and validation.

Build a Complete Cooling Loop Monitoring Solution

FMV-040-IOL

Vortex Flow Sensor

THH06N-G1/4-Lxx-IL-SC

Temperature Transmitter

LTH-G1/2N-LI6D-SC/Lxxx

Liquid Level/Temperature Sensor

TBH-18ME-LI6D-SC

Temperature Sensor with Display

You're on the application landing page for Data Center Liquid Cooling. Detaled specifcations, variants, and accesories are avalable on each product page.

Technical Files for Fast Evaluation

Download IO-Link Profile

Dowload CAD Model

Download Wiring Diagram

Need further engineering support? Our team is ready to assist you.

Coolant Compatibility

coolant Type

Recommendation

water

Standard application

Treated water

Compatibility check recommended

Low-conductivity DI water

Compatibilty check recommnended

Water + Glycol mixture

Suitable in acoordance with viscosity

Dielectric (3M/Immersion)

Not recommended without validation

Two-phase (fluorinated)

Not recommended without validation

Why Choose Sentinel for Liquid Cooling Field Monitoring?

IO-Link Scene Expertise

Application-Driven Solutions

European Support

Fast Technical Files

OEM & Integrator Support

EU Delivery Support

Related Articles

Insights and best practices for data center liquid cooling and industrial sensing.

SENTINEL’s Monitoring Solution Blueprint for Data Center Liquid Cooling

CDU Liquid Cooling in the High-Compute Data Center Era: Upgrading from “Running” to “Operations Management”

Why the On-Site Liquid Cooling Layer Becomes More Critical as AI Data Centers Grow More Costly

What Liquid Cooling Systems Really Need Is Not Just Alarms, but an Explainable Operating Status

Why Are More and More Field Devices Starting to Support IO-Link?

In a liquid cooling system, if the flow sensor value starts to drop slowly, it may indicate filter blockage or pump operating deviation.

Insights and best practices for data center liquid cooling and industrial sensing.


Let Us Help You Build a Reliableand Efficient Cooling System

 

Share your application detalls and our engineers willrecommend the right solution, provide technicalfiles, and support your project from evaluationto implementation.